Your Trusted Source for Industrial Electrical Components

LA 205-S/SP1

Closed loop (compensated)

LEM | LA-Series | Closed loop (compensated) | EN 50178

± 12 .. 15 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
100 mASecondary nominal r.m.s. current (I)
1625 VR.m.s rated voltage 2), safe separation (V)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 300
Supply Voltage± 12 .. 15 V
Operating Temperature Range- 10 .. + 85
Current Consumption (IC)20 (@ ± 15 V) + I mA Advantages
Primary nominal r.m.s. current (I)200 A
Measuring overload (Î)600 A

Standards & Approvals

  • EN 50178 :

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LA 205-S/SP1 is a closed loop (compensated) current transducer from LEM.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: frequency bandwidth DC .. 100 kHz; operating temperature - 10 .. + 85.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLA
Product ReferenceLA 205-S/SP1
Supply Voltage± 12 .. 15 V
Measurement—
Mounting—
Application Domain—
Electrical Data — LA 205-S/SP1
Primary Current, Measuring Range (IPM)0 .. ± 300
Supply Voltage (UC)± 12 .. 15 V
Current Consumption (IC)20 (@ ± 15 V) + I mA Advantages
Primary nominal r.m.s. current (I)200 A
Primary current, measuring range (I)0 .. ± 300 A
Measuring overload (Î)600 A
Secondary nominal r.m.s. current (I)100 mA
Supply voltage (± 5 %) (V)± 12 .. 15 V
R.m.s rated voltage 2), safe separation (V)1625 V
Accuracy & Dynamic Performance
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Thermal drift of I (I)- 10°C .. + 85°C ± 0.15 ± 0.30 mA
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 10 .. + 85
Ambient Storage Temperature (TA st)- 40 .. + 90
Mass (m)110 g
Ambient operating temperature (T)- 10 .. + 85 °C
Ambient storage temperature (T)- 40 .. + 90 °C
Standards & Certifications
EN 50178:
Standards EN 50178 :1997

Note: Specifications are taken from the official LA 205-S/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LA 205-S/SP1 are shown below.

LA 205-S/SP1 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LA 205-S/SP1 datasheet, page 2
Outline Dimensions & Mechanical Data
Mass110 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LA 205-S/SP1.

UNVERIFIED

Characteristic Curves

Characteristic curve diagrams are not included in the LA 205-S/SP1 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment