Your Trusted Source for Industrial Electrical Components

LA 205-S/SP6

Closed loop (compensated)

LEM | LA-Series | Closed loop (compensated) | 5) EN 50155 (01.

± 12 .. 15 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
100 mASecondary nominal r.m.s. current (I)
6 kVR.m.s. voltage for AC isolation test, 50 Hz, 1 mn (V)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 300
Supply Voltage± 12 .. 15 V
Operating Temperature Range- 40 .. + 85
Current Consumption (IC)20 (@ ± 15 V) + I mA
Primary nominal r.m.s. current (I)200 A
Measuring overload600 A

Standards & Approvals

  • 5) EN 50155 (01.

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLA
Product ReferenceLA 205-S/SP6
Supply Voltage± 12 .. 15 V
Measurement—
Mounting—
Application Domain—
Electrical Data — LA 205-S/SP6
Primary Current, Measuring Range (IPM)0 .. ± 300
Supply Voltage (UC)± 12 .. 15 V
Current Consumption (IC)20 (@ ± 15 V) + I mA
Primary nominal r.m.s. current (I)200 A
Primary current, measuring range (I)0 .. ± 300 A
Measuring overload600 A
Secondary nominal r.m.s. current (I)100 mA
Supply voltage (± 5 %) (V)± 12 .. 15 V
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn (V)6 kV
R.m.s. rated voltage 2), safe separation (V)1625 V
Accuracy & Dynamic Performance
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity< 0.1 %
Thermal drift of I (I)- 40°C .. + 85°C ± 0.20 ± 0.50 mA
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 40 .. + 85
Ambient Storage Temperature (TA st)- 50 .. + 90
Mass (m)150 g
Ambient operating temperature (T)- 40 .. + 85 °C
Ambient storage temperature (T)- 50 .. + 90 °C
Standards & Certifications
5) EN 50155 (01.

Note: Specifications are taken from the official LA 205-S/SP6 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LA 205-S/SP6 are shown below.

LA 205-S/SP6 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LA 205-S/SP6 datasheet, page 2
Outline Dimensions & Mechanical Data
Mass150 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LA 205-S/SP6.

UNVERIFIED

Characteristic Curves

Characteristic curve diagrams are not included in the LA 205-S/SP6 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity< 0.1 %
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment