Your Trusted Source for Industrial Electrical Components

LA 255-S

Closed loop (compensated)

LEM | LA-Series | Closed loop (compensated) | 5) EN

± 12 .. 18 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
< 0.1 %Linearity Error (Max)
125 mASecondary nominal r.m.s. current (I)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 500
Supply Voltage± 12 .. 18 V
Operating Temperature Range- 10 .. + 85
Current Consumption (IC)20 (@ ± 15 V) + I S mA • High immunity to external
Primary nominal r.m.s. current (I)250 A
Measuring overload (Î)600 A

Standards & Approvals

  • 5) EN

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLA
Product ReferenceLA 255-S
Supply Voltage± 12 .. 18 V
Measurement—
Mounting—
Application Domain—
Electrical Data — LA 255-S
Primary Current, Measuring Range (IPM)0 .. ± 500
Supply Voltage (UC)± 12 .. 18 V
Current Consumption (IC)20 (@ ± 15 V) + I S mA • High immunity to external
Primary nominal r.m.s. current (I)250 A
Primary current, measuring range (I)0 .. ± 500 A
Measuring overload (Î)600 A
Secondary nominal r.m.s. current (I)125 mA
Supply voltage (± 5 %) (V)± 12 .. 18 V
R.m.s. rated voltage 2), safe separation (V)1625 V
Accuracy & Dynamic Performance
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Thermal drift of I (I)- 10°C .. + 85°C ± 0.15 ± 0.30 mA
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 10 .. + 85
Ambient Storage Temperature (TA st)- 40 .. + 90
Mass (m)110 g
Ambient operating temperature (T)- 10 .. + 85 °C
Ambient storage temperature (T)- 40 .. + 90 °C
Standards & Certifications
5) EN
Standards 5) EN50178

Note: Specifications are taken from the official LA 255-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LA 255-S are shown below.

LA 255-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LA 255-S datasheet, page 2
Outline Dimensions & Mechanical Data
Mass110 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LA 255-S.

UNVERIFIED

Characteristic Curves

Characteristic curve diagrams are not included in the LA 255-S datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Frequency bandwidth (- 3 dB) (f)DC .. 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment