Your Trusted Source for Industrial Electrical Components

LA 205-S/SP33

Closed loop (compensated) current transducer using the Hall effect

LEM | LA-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

± 15 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
< 0.1 %Linearity Error (Max)
600 AMeasuring overload (Î)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 600 A
Supply Voltage± 15 V
Operating Temperature Range- 40 .. + 70 °C
Isolation Test Voltage6 kV
Current Consumption (IC)20 + I mA A
Primary nominal current rms (I)300 A

Standards & Approvals

  • EN 50155:

Typical Applications

Single or three phase inverter, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger. Application Domain, Traction. Page 1/3 prior notice. www.lem.com

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LA 205-S/SP33 is a closed loop (compensated) current transducer from LEM.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverter, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: linearity error < 0.1 %; frequency bandwidth DC .. 100 kHz; operating temperature - 40 .. + 70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLA
Product ReferenceLA 205-S/SP33
Primary Nominal Current300 A
Supply Voltage± 15 V
Measurement—
MountingBusbar Mount
Application DomainTraction
Electrical Data — LA 205-S/SP33
Primary Current, Measuring Range (IPM)0 .. ± 600 A
Supply Voltage (UC)± 15 V
Current Consumption (IC)20 + I mA A
Primary nominal current rms (I)300 A
Primary current, measuring range (I)0 .. ± 600 A
Measuring overload (Î)600 A
Secondary nominal current rms150 mA
Supply voltage (± 5 %)± 15 V
Current consumption20 mA
Accuracy & Dynamic Performance
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Temperature variation of I (I)- 40°C .. + 70°C ± 0.20 ± 0.50 mA
Response time 3) to 90 % of I step (t)< 1 µs
BW Frequency bandwidth (- 3 dB)DC .. 100 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Creepage Distance (dCp)32.8 mm
Rms voltage for AC isolation test, 50 Hz (V)1 min 6 kV
Rated isolation voltage rms 4), reinforced isolation (V)1625 V
CTI Comparative Tracking Index (group IIIa)225
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 40 .. + 70 °C
Ambient Storage Temperature (TA st)- 50 .. + 95 °C
Mass (m)190 g
Ambient operating temperature (T)- 40 .. + 70 °C
Ambient storage temperature (T)- 50 .. + 95 °C
Standards & Certifications
EN 50155Compliance
Standards EN 50155:1995

Note: Specifications are taken from the official LA 205-S/SP33 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LA 205-S/SP33 are shown below.

LA 205-S/SP33 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LA 205-S/SP33 datasheet, page 3
Outline Dimensions & Mechanical Data
Mass190 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LA 205-S/SP33.

Single or three phase inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger. Application Domain
Traction. Page 1/3 prior notice. www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LA 205-S/SP33 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC .. 100 kHz
Linearity error< 0.1 %
Response time 3) to 90 % of I step (t)< 1 µs
BW Frequency bandwidth (- 3 dB)DC .. 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment