Your Trusted Source for Industrial Electrical Components

DILM115

Contactors

Eaton | Contactors | 239567

115 AAmperage
690 VVoltage
1150 ABreaking Capacity
55 kWRated Power
ContactorsProduct Type

Additional Technical Details

View Full Specifications
Product Weight2.25 kg
Product Length/Depth160 mm
Product Height170 mm
Product Width90 mm
ConnectionScrew terminals
Number Of PolesThree-pole

Standards & Approvals

  • 3211-04

Typical Applications

Motor Control, Pumps & Fans, HVAC Systems and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM contactor
Catalog Number239567
EAN4015082395674
Model CodeDILM115(RDC130)
Product categoryContactors
Voltage typeDC
Short-circuit protection rating (type 1 coordination) at 400 V250 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V250 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V250 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V250 A gG/gL
Electrical Characteristics
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency3600 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Rated impulse withstand voltage (Uimp)8000 V AC
Residual current1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
Resistance per pole0.6 mΩ
Utilization categoryAC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Shock resistance7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Rated breaking capacity at 220/230 V1150 A
Rated breaking capacity at 380/400 V1150 A
Rated breaking capacity at 500 V1150 A
Rated breaking capacity at 660/690 V1100 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V160 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V115 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V115 A
Rated operational current (Ie) at AC-3, 440 V115 A
Rated operational current (Ie) at AC-3, 500 V115 A
Rated operational current (Ie) at AC-3, 660 V, 690 V93 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V55 A
Rated operational current (Ie) at AC-4, 400 V55 A
Rated operational current (Ie) at AC-4, 500 V55 A
Rated operational current (Ie) at AC-4, 660 V, 690 V45 A
Rated operational current (Ie) at DC-1, 60 V160 A
Rated operational current (Ie) at DC-1, 110 V160 A
Rated operational current (Ie) at DC-1, 220 V90 A
Rated insulation voltage (Ui)690 V
Rated operational power at AC-3, 240 V, 50 Hz40 kW
Rated operational power at AC-3, 380/400 V, 50 Hz55 kW
Rated operational power at AC-3, 415 V, 50 Hz70 kW
Rated operational power at AC-4, 220/230 V, 50 Hz17 kW
Rated operational power at AC-4, 240 V, 50 Hz19 kW
Rated operational power at AC-4, 415 V, 50 Hz33 kW
Rated operational power at AC-4, 440 V, 50 Hz35 kW
Rated operational power at AC-4, 500 V, 50 Hz40 kW
Rated operational power at AC-4, 660/690 V, 50 Hz43 kW
Rated operational voltage (Ue) at AC - max690 V
Short-circuit current rating (basic rating)10 kA, 600 A max. fuse, SCCR (UL/CSA) 10 kA, 600 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 300 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 600 A max. fuse, SCCR (UL/CSA) 65 kA, 250 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 300 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 600 A max. fuse, SCCR (UL/CSA)
Conventional thermal current Ith (1-pole, enclosed)285 A
Conventional thermal current Ith (3-pole, enclosed)115 A
Conventional thermal current Ith at 55°C (3-pole, open)135 A
Conventional thermal current Ith of main contacts (1-pole, open)325 A
Switching capacity (main contacts, general use)180 A, Maximum motor rating (UL/CSA)
Arcing time15 ms
Drop-out voltage0.6 - 0.15 x UC, DC operated At least smoothed two-phase bridge rectifier or three-phase rectifier
Duty factor100 %
Pick-up voltage0.7 - 1.2 V DC x Uc 110 - 130 V DC (RDC 130)
Power consumption (pick-up) at DC149 W
Power consumption (sealing) at DC1.9 W
Rated control supply voltage (Us) at DC - min110 V
Rated control supply voltage (Us) at DC - max130 V
Assigned motor power at 115/120 V, 60 Hz, 1-phase10 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase40 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase25 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase50 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase100 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase100 HP
Safe isolation690 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140
Special purpose rating of resistance air heating160 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 160 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Equipment heat dissipation, current-dependent Pvid18.9 W
Heat dissipation capacity Pdiss0 W
Rated operational current for specified heat dissipation (In)115 A
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
Mechanical & Physical
Product Length/Depth160 mm
Product Height170 mm
Product Width90 mm
Product Weight2.25 kg
Fitted with:Suppressor circuit in actuating electronics
Number of polesThree-pole
Frame sizeFS4
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Terminal capacity (copper band)2 x (6 x 16 x 0.8) mm (Number of segments x width x thickness), Main cables
Terminal capacity (flexible with ferrule)1 x (10 - 95) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (10 - 70) mm², Main cables 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)1 x (0.75 - 4) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)18 - 14, Control circuit cables Single 8…3/0, double 8…2/0, Main cables
Terminal capacity (stranded)1 x (16 - 95) mm², Main cables 2 x (16 - 70) mm², Main cables
Stripping length (main cable)24 mm
Stripping length (control circuit cable)10 mm
Screw sizeM10, Terminal screw, Main cables 5 mm AF, Hexagon socket-head spanner, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver 2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Tightening torque14 Nm, Screw terminals, Main cables 1.2 Nm, Screw terminals, Control circuit cables
Switching time (DC operated, make contacts, closing delay) - max35 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
ConnectionScrew terminals
Connection to SmartWire-DTNo
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Environmental & Compliance
CertificationsUL CSA File No.: 012528 UL 60947-4-1 UL Category Control No.: NLDX VDE 0660 CSA-C22.2 No. 60947-4-1-14 CSA IEC/EN 60947-4-1 CE IEC/EN 60947 UL File No.: E29096 CSA Class No.: 2411-03, 3211-04
Pollution degree3
Ambient operating temperature - min-25 °C
Ambient operating temperature - max60 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient storage temperature - min-40 °C
Ambient storage temperature - max80 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Additional Specifications
Catalog NotesContacts according to EN 50012
ApplicationContactors for Motors
Suitable forAlso motors with efficiency class IE3
Special purpose rating of ballast electrical discharge lamps160 A (600V 60Hz 3phase, 347V 60Hz 1phase) 160 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Special purpose rating of definite purpose rating115 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 690 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control100 HP, 600 V 60 Hz 3-ph, (UL/CSA) 92 A, 200 V 60 Hz 3-ph, (UL/CSA) 96 A, 480 V 60 Hz 3-ph, (UL/CSA) 75 HP, 480 V 60 Hz 3-ph, (UL/CSA) 30 HP, 200 V 60 Hz 3-ph, (UL/CSA) 40 HP, 240 V 60 Hz 3-ph, (UL/CSA) 99 A, 600 V 60 Hz 3-ph, (UL/CSA) 104 A, 240 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)84 A, FLA 600 V 60 Hz 3phase; (CSA) 84 A, FLA 480 V 60 Hz 3phase; (CSA) 540 A, LRA 480 V 60 Hz 3phase; (CSA) 540 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of tungsten incandescent lamps160 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 160 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Note: Specifications are taken from the official Eaton DILM115 datasheet.

Documents & Downloads

Official technical documentation for the DILM115.

Typical Applications

Typical applications of the DILM115.

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment