Your Trusted Source for Industrial Electrical Components

DILM17-01

Contactor

Eaton | Contactors | 277050

18 AAmperage
690 VVoltage
170 ABreaking Capacity
7.5 kWRated Power
ContactorProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.534 kg
Product Length/Depth97 mm
Product Height85 mm
Product Width45 mm
Degree Of ProtectionIP00
ConnectionScrew terminals

Standards & Approvals

  • 3211-04 CSA VDE 0660

Typical Applications

Motor Control, Pumps & Fans, HVAC Systems and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM contactor
Catalog Number277050
Model CodeDILM17-01(RDC24)
EAN4015082770501
Product TypeContactor
Product categoryContactors
Voltage typeDC
Short-circuit protection rating (type 1 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V35 A gG/gL
Electrical Characteristics
Shock resistance7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Conventional thermal current Ith (1-pole, enclosed)80 A
Conventional thermal current Ith (3-pole, enclosed)32 A
Conventional thermal current Ith at 55°C (3-pole, open)37 A
Conventional thermal current Ith at 60°C (3-pole, open)35 A
Conventional thermal current Ith of main contacts (1-pole, open)88 A
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid2.1 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.7 W
Rated operational current for specified heat dissipation (In)18 A
Static heat dissipation, non-current-dependent Pvs0.9 W
Rated breaking capacity at 220/230 V170 A
Rated breaking capacity at 380/400 V170 A
Rated breaking capacity at 500 V170 A
Rated breaking capacity at 660/690 V120 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)238 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V40 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V18 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V18 A
Rated operational current (Ie) at AC-3, 440 V18 A
Rated operational current (Ie) at AC-3, 500 V18 A
Rated operational current (Ie) at AC-3, 660 V, 690 V12 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V10 A
Rated operational current (Ie) at AC-4, 440 V10 A
Rated operational current (Ie) at AC-4, 500 V10 A
Rated operational current (Ie) at AC-4, 660 V, 690 V8 A
Rated operational current (Ie) at DC-1, 110 V35 A
Rated operational current (Ie) at DC-1, 220 V35 A
Rated operational current (Ie) at DC-1, 60 V35 A
Rated operational power at AC-3, 240 V, 50 Hz5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz7.5 kW
Rated operational power at AC-3, 415 V, 50 Hz10 kW
Rated operational power at AC-3, 440 V, 50 Hz10.5 kW
Rated operational power at AC-3, 500 V, 50 Hz12 kW
Rated operational power at AC-3, 690 V, 50 Hz11 kW
Rated operational power at AC-4, 220/230 V, 50 Hz2.5 kW
Rated operational power at AC-4, 240 V, 50 Hz3 kW
Rated operational power at AC-4, 415 V, 50 Hz5 kW
Rated operational power at AC-4, 440 V, 50 Hz5.5 kW
Rated operational power at AC-4, 500 V, 50 Hz6 kW
Rated operational power at AC-4, 660/690 V, 50 Hz6.5 kW
Rated operational voltage (Ue) at AC - max690 V
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency5000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole2.7 mΩ
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-3: Normal AC induction motors: starting, switch off during running
Arcing time10 ms
Drop-out voltage0.6 - 0.15 x UC, DC operated At least smoothed two-phase bridge rectifier or three-phase rectifier
Duty factor100 %
Pick-up voltage24 - 27 V DC (RDC 24) 0.7 - 1.2 V DC x Uc
Power consumption (pick-up) at DC12 W
Power consumption (sealing) at DC0.9 W
Rated control supply voltage (Us) at DC - max27 V
Rated control supply voltage (Us) at DC - min24 V
Assigned motor power at 115/120 V, 60 Hz, 1-phase2 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase5 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase15 HP
Safe isolation440 V AC, Between coil and contacts, According to EN 61140 440 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)125 A, max. Fuse, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA) 125 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) 10/65 kA, CB, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA)
Special purpose rating of resistance air heating40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)40 A, Maximum motor rating (UL/CSA)
Mechanical & Physical
Product Length/Depth97 mm
Product Height85 mm
Product Width45 mm
Product Weight0.534 kg
Connection to SmartWire-DTYes In conjunction with DIL-SWD SmartWire DT contactor module
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)1
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed contacts)1
Number of contacts (normally closed) as main contact0
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:Suppressor circuit in actuating electronics Mirror contact
Number of polesThree-pole
ConnectionScrew terminals
Degree of protectionIP00
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Frame sizeFS2
Switching time (DC operated, make contacts, closing delay) - max47 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
Screw sizeM5, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables
Screwdriver size2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)1 x (0.75 - 16) mm², Main cables 2 x (0.75 - 10) mm², Main cables 1 x (0.75 - 4) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (stranded)1 x 16 mm², Main cables
Tightening torque1.2 Nm, Screw terminals, Control circuit cables 3.2 Nm, Screw terminals, Main cables
Terminal capacity (flexible with ferrule)2 x (0.75 - 10) mm², Main cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 16) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)Single 18 - 6, double 18 - 8, Main cables 18 - 14, Control circuit cables
Environmental & Compliance
CertificationsUL File No.: E29096 CE IEC/EN 60947 IEC/EN 60947-4-1 UL Category Control No.: NLDX UL CSA File No.: 012528 CSA-C22.2 No. 60947-4-1-14 UL 60947-4-1 CSA Class No.: 2411-03, 3211-04 CSA VDE 0660
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Pollution degree3
Additional Specifications
Catalog NotesContacts according to EN 50012
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
ApplicationContactors for Motors
Suitable forAlso motors with efficiency class IE3
Special purpose rating of definite purpose rating18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control3 HP, 240 V 60 Hz 3-ph, (UL/CSA) 11 A, 600 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 10 HP, 600 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 11 A, 480 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)40 A, FLA 480 V 60 Hz 3phase; (CSA) 240 A, LRA 480 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA) 180 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of tungsten incandescent lamps40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps40 A (600V 60Hz 3phase, 347V 60Hz 1phase) 40 A (480V 60Hz 3phase, 277V 60Hz 1phase)

Note: Specifications are taken from the official Eaton DILM17-01 datasheet.

Documents & Downloads

Official technical documentation for the DILM17-01.

Typical Applications

Typical applications of the DILM17-01.

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment