Your Trusted Source for Industrial Electrical Components

DILM15-10

Contactors

Eaton | Contactors | 290073

15.5 AAmperage
690 VVoltage
124 ABreaking Capacity
7.5 kWRated Power
ContactorsProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.296 kg
Product Length/Depth75 mm
Product Height68 mm
Product Width45 mm
Degree Of ProtectionIP20
ConnectionScrew terminals

Standards & Approvals

  • 3211-04 CE UL CSA

Typical Applications

Motor Control, Pumps & Fans, HVAC Systems and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM contactor
Catalog Number290073
Model CodeDILM15-10(24VDC)
EAN4015082900731
Product categoryContactors
Voltage typeDC
Short-circuit protection rating (type 1 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V20 A gG/gL
Electrical Characteristics
Shock resistance7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Conventional thermal current Ith (1-pole, enclosed)45 A
Conventional thermal current Ith (3-pole, enclosed)18 A
Conventional thermal current Ith at 55°C (3-pole, open)21 A
Conventional thermal current Ith of main contacts (1-pole, open)50 A
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid2.4 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.8 W
Rated operational current for specified heat dissipation (In)15.5 A
Static heat dissipation, non-current-dependent Pvs4.5 W
Rated breaking capacity at 220/230 V124 A
Rated breaking capacity at 380/400 V124 A
Rated breaking capacity at 500 V100 A
Rated breaking capacity at 660/690 V70 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)155 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V22 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V15.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V15.5 A
Rated operational current (Ie) at AC-3, 440 V15.5 A
Rated operational current (Ie) at AC-3, 500 V12.5 A
Rated operational current (Ie) at AC-3, 660 V, 690 V9 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V7 A
Rated operational current (Ie) at AC-4, 440 V7 A
Rated operational current (Ie) at AC-4, 500 V6 A
Rated operational current (Ie) at AC-4, 660 V, 690 V5 A
Rated operational current (Ie) at DC-1, 110 V20 A
Rated operational current (Ie) at DC-1, 220 V15 A
Rated operational current (Ie) at DC-1, 60 V20 A
Rated operational power at AC-3, 240 V, 50 Hz4.6 kW
Rated operational power at AC-3, 380/400 V, 50 Hz7.5 kW
Rated operational power at AC-3, 415 V, 50 Hz8 kW
Rated operational power at AC-4, 220/230 V, 50 Hz2 kW
Rated operational power at AC-4, 240 V, 50 Hz2.2 kW
Rated operational power at AC-4, 415 V, 50 Hz3.4 kW
Rated operational power at AC-4, 440 V, 50 Hz3.6 kW
Rated operational power at AC-4, 500 V, 50 Hz3.5 kW
Rated operational power at AC-4, 660/690 V, 50 Hz4.4 kW
Rated operational voltage (Ue) at AC - max690 V
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency5000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole4.6 mΩ
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Arcing time10 ms
Drop-out voltage0.6 - 0.15 x UC, DC operated At least smoothed two-phase bridge rectifier or three-phase rectifier
Duty factor100 %
Pick-up voltage0.7 - 1.3 V DC x Uc (without auxiliary contact module and at ambient air temperature + 40 °C) 0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts) 0.8 - 1.1 V DC x Uc
Power consumption (pick-up) at DC4.5 W
Power consumption (sealing) at DC4.5 W
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Assigned motor power at 115/120 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase5 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase10 HP
Safe isolation400 V AC, Between the contacts, According to EN 61140 400 V AC, Between coil and contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 45 A max. fuse, SCCR (UL/CSA) 5 kA, 45 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Special purpose rating of resistance air heating20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)20 A, Maximum motor rating (UL/CSA)
Mechanical & Physical
Product Length/Depth75 mm
Product Height68 mm
Product Width45 mm
Product Weight0.296 kg
Connection to SmartWire-DTYes In conjunction with DIL-SWD SmartWire DT contactor module
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)1
Number of contacts (normally open contacts)1
Number of contacts (normally closed) as main contact0
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:Varistor suppressor circuit
Number of polesThree-pole
ConnectionScrew terminals
Degree of protectionIP20
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Switching time (DC operated, make contacts, closing delay) - max31 ms
Switching time (DC operated, make contacts, opening delay) - max12 ms
Screw sizeM3.5, Terminal screw
Screwdriver size2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)1 x (0.75 - 4) mm² 2 x (0.75 - 2.5) mm²
Tightening torque1.2 Nm, Screw terminals
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm² 1 x (0.75 - 2.5) mm²
Terminal capacity (solid/stranded AWG)Single 18 - 10, double 18 - 14
Environmental & Compliance
CertificationsUL Category Control No.: NLDX CSA File No.: 012528 UL File No.: E29096 IEC/EN 60947-4-1 IEC/EN 60947 VDE 0660 CSA-C22.2 No. 60947-4-1-14 UL 60947-4-1 CSA Class No.: 2411-03, 3211-04 CE UL CSA
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Pollution degree3
Additional Specifications
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
ApplicationContactors for Motors
Special purpose rating of definite purpose rating15 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 90 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 11 A, 480 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 9 A, 600 V 60 Hz 3-ph, (UL/CSA) 3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)10 A, FLA 600 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of tungsten incandescent lamps14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps20 A (480V 60Hz 3phase, 277V 60Hz 1phase) 20 A (600V 60Hz 3phase, 347V 60Hz 1phase)

Note: Specifications are taken from the official Eaton DILM15-10 datasheet.

Documents & Downloads

Official technical documentation for the DILM15-10.

Typical Applications

Typical applications of the DILM15-10.

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment