Your Trusted Source for Industrial Electrical Components
Home Products Eaton Contactors DILM12-10(24V60HZ)

DILM12-10(24V60HZ)

Contactor

Eaton | Contactors | DILM12-10(24V60HZ)

ContactorProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.24 kg
Product Length/Depth75 mm
Product Height68 mm
Product Width45 mm

Standards & Approvals

  • CSA-C22.2 No. 14-05
  • VDE 0660
  • IEC/EN 60947-4-1
  • UL 508
  • UL
  • CSA

Typical Applications

Contactors for Motors

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM contactor
Catalog Number276821
Model CodeDILM12-10(24V60HZ)
EAN4015082768218
Product Length/Depth75 mm
Product Height68 mm
Product Width45 mm
Product Weight0.24 kg
CertificationsCSA-C22.2 No. 14-05 VDE 0660 UL Category Control No.: NLDX IEC/EN 60947-4-1 UL 508 UL CSA CSA File No.: 012528 CSA Class No.: 2411-03, 3211-04 CE IEC/EN 60947 UL File No.: E29096
Catalog NotesContacts according to EN 50012
Product TypeContactor
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP20
Lifespan, mechanical10,000,000 Operations (AC operated)
Operating frequency9000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole2.5 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeAC
Frame sizeFS1
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.3 W
Rated operational current for specified heat dissipation (In)12 A
Static heat dissipation, non-current-dependent Pvs1.4 W
Electrical Characteristics
Rated breaking capacity at 220/230 V120 A
Rated breaking capacity at 380/400 V120 A
Rated breaking capacity at 500 V100 A
Rated breaking capacity at 660/690 V70 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)144 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V22 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V12 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V12 A
Rated operational current (Ie) at AC-3, 440 V12 A
Rated operational current (Ie) at AC-3, 500 V10 A
Rated operational current (Ie) at AC-3, 660 V, 690 V7 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V7 A
Rated operational current (Ie) at AC-4, 440 V7 A
Rated operational current (Ie) at AC-4, 500 V6 A
Rated operational current (Ie) at AC-4, 660 V, 690 V5 A
Rated operational current (Ie) at DC-1, 110 V20 A
Rated operational current (Ie) at DC-1, 220 V15 A
Rated operational current (Ie) at DC-1, 60 V20 A
Rated operational power at AC-3, 240 V, 50 Hz4 kW
Rated operational power at AC-3, 380/400 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz7 kW
Rated operational power at AC-3, 440 V, 50 Hz7.5 kW
Rated operational power at AC-3, 500 V, 50 Hz7 kW
Rated operational power at AC-3, 690 V, 50 Hz6.5 kW
Rated operational power at AC-4, 220/230 V, 50 Hz2 kW
Rated operational power at AC-4, 240 V, 50 Hz2.2 kW
Rated operational power at AC-4, 415 V, 50 Hz3.4 kW
Rated operational power at AC-4, 440 V, 50 Hz3.6 kW
Rated operational power at AC-4, 500 V, 50 Hz3.5 kW
Rated operational power at AC-4, 660/690 V, 50 Hz4.4 kW
Rated operational voltage (Ue) at AC - max690 V
Coil & Magnet System
Arcing time10 ms
Drop-out voltageAC operated: 0.6 - 0.3 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz24 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, pick-up, 60 Hz30 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Power consumption, sealing, 50 Hz3.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, sealing, 60 Hz4.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Rated control supply voltage (Us) at AC, 50 Hz - max0 V
Rated control supply voltage (Us) at AC, 50 Hz - min0 V
Rated control supply voltage (Us) at AC, 60 Hz - max24 V
Rated control supply voltage (Us) at AC, 60 Hz - min24 V
Rated control supply voltage (Us) at DC - max0 V
Rated control supply voltage (Us) at DC - min0 V
Switching time (AC operated, make contacts, closing delay) - max21 ms
Switching time (AC operated, make contacts, closing delay) - min15 ms
Switching time (AC operated, make contacts, opening delay) - max18 ms
Switching time (AC operated, make contacts, opening delay) - min9 ms
Terminal Capacities
Screw sizeM3.5, Terminal screw
Screwdriver size2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)2 x (0.75 - 2.5) mm² 1 x (0.75 - 4) mm²
Tightening torque1.2 Nm, Screw terminals
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm² 2 x (0.75 - 2,5) mm² 2 x (0.75 - 2.5) mm²
Terminal capacity (solid/stranded AWG)Single 18 - 10, double 18 - 14
Thu Nov 05 2026
Eaton Moeller® series DILM contactor
276821
DILM12-10(24V60HZ)
4015082768218
75 mm
68 mm
45 mm
0.24 kg
CSA-C22.2 No. 14-05
Contacts according to EN 50012
Contactor
Max. 2000 m
60 °C
80 °C
Additional Specifications
Connection to SmartWire-DTNo
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Number of polesThree-pole
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300, DC operated (UL/CSA) A600, AC operated (UL/CSA)
Switching capacity (main contacts, general use)20 A, Maximum motor rating (UL/CSA)
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)1
Number of contacts (normally open contacts)1
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)45 A
Conventional thermal current Ith (3-pole, enclosed)18 A
Conventional thermal current Ith at 55°C (3-pole, open)21 A
Conventional thermal current Ith at 60°C (3-pole, open)20 A
Conventional thermal current Ith of main contacts (1-pole, open)50 A
Assigned motor power at 115/120 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase2 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase10 HP
Special purpose rating of definite purpose rating72 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 12 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control11 A, 480 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 9 A, 600 V 60 Hz 3-ph, (UL/CSA) 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA) 2 HP, 240 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)10 A, FLA 600 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) 10 A, FLA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps20 A (600V 60Hz 3phase, 347V 60Hz 1phase) 20 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Short-circuit current rating (basic rating)5 kA, SCCR (UL/CSA) 45 A, max. Fuse, SCCR (UL/CSA) 60 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)25 A, Class RK5/ 45 A Class J, max. Fuse, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)30/100 kA, Fuse, SCCR (UL/CSA) 25 A, Class RK5/45 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V25 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V20 A gG/gL
Shock resistance3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
Safe isolation400 V AC, Between the contacts, According to EN 61140 400 V AC, Between coil and contacts, According to EN 61140

Note: Specifications are taken from the official Eaton DILM12-10(24V60HZ) product data sheet.

Documents & Downloads

Official technical documentation for the DILM12-10(24V60HZ).

Typical Applications

Typical applications of the DILM12-10(24V60HZ).

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment