Your Trusted Source for Industrial Electrical Components

DILM185

Contactors

Eaton | Contactors | 139537

76 AAmperage
1000 VVoltage
760 ABreaking Capacity
90 kWRated Power
ContactorsProduct Type

Additional Technical Details

View Full Specifications
Product Weight3.54 kg
Product Length/Depth158 mm
Product Height190 mm
Product Width140 mm
Degree Of ProtectionIP00
ConnectionScrew terminals

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Motor Control, Pumps & Fans, HVAC Systems and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM Contactor
Catalog Number139537
EAN4015081363155
Model CodeDILM185A/22(RAC240)
Product categoryContactors
Voltage typeAC
Short-circuit protection rating (type 1 coordination) at 1000 V200 A gG/gL
Short-circuit protection rating (type 1 coordination) at 400 V400 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V315 A gG/gL
Short-circuit protection rating (type 2 coordination) at 1000 V160 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V315 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V250 A gG/gL
Electrical Characteristics
Conventional thermal current Ith (1-pole, enclosed)613 A
Conventional thermal current Ith (3-pole, enclosed)245 A
Conventional thermal current Ith at 40°C (3-pole, open)337 A
Conventional thermal current Ith at 50°C (3-pole, open)301 A
Conventional thermal current Ith at 55°C (3-pole, open)287 A
Conventional thermal current Ith at 60°C (3-pole, open)275 A
Conventional thermal current Ith of main contacts (1-pole, open)688 A
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid16 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid5.33 W
Rated operational current for specified heat dissipation (In)185 A
Static heat dissipation, non-current-dependent Pvs2.1 W
Inrush currentMax. 30 x Ie (peak)
Rated breaking capacity at 1000 V760 A
Rated breaking capacity at 220/230 V2250 A
Rated breaking capacity at 380/400 V2250 A
Rated breaking capacity at 500 V2250 A
Rated breaking capacity at 660/690 V2250 A
Rated insulation voltage (Ui)1000 V
Rated making capacity (cos phi to IEC/EN 60947)2700 A
Rated operational current (Ie)220 A at up to 525 V (Individual compensation, three-phase capacitors, open) 133 A at 690 V (Individual compensation, three-phase capacitors, open)
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V337 A
Rated operational current (Ie) at AC-3, 1000 V76 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V185 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V185 A
Rated operational current (Ie) at AC-3, 440 V185 A
Rated operational current (Ie) at AC-3, 500 V185 A
Rated operational current (Ie) at AC-3, 660 V, 690 V150 A
Rated operational current (Ie) at AC-4, 1000 V55 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V136 A
Rated operational current (Ie) at AC-4, 440 V136 A
Rated operational current (Ie) at AC-4, 500 V136 A
Rated operational current (Ie) at AC-4, 660 V, 690 V110 A
Rated operational power at AC-3, 1000 V, 50 Hz108 kW
Rated operational power at AC-3, 240 V, 50 Hz62 kW
Rated operational power at AC-3, 380/400 V, 50 Hz90 kW
Rated operational power at AC-3, 415 V, 50 Hz110 kW
Rated operational power at AC-3, 440 V, 50 Hz115 kW
Rated operational power at AC-3, 500 V, 50 Hz132 kW
Rated operational power at AC-3, 690 V, 50 Hz140 kW
Rated operational power at AC-4, 1000 V, 50 Hz77 kW
Rated operational power at AC-4, 220/230 V, 50 Hz41 kW
Rated operational power at AC-4, 240 V, 50 Hz45 kW
Rated operational power at AC-4, 415 V, 50 Hz80 kW
Rated operational power at AC-4, 440 V, 50 Hz85 kW
Rated operational power at AC-4, 500 V, 50 Hz96 kW
Rated operational power at AC-4, 660/690 V, 50 Hz102 kW
Rated operational voltage (Ue) at AC - max1000 V
Safe isolation1000 V AC, Between coil and contacts, According to EN 61140
Lifespan, electrical100,000 Operations (at Condensor operation)
Lifespan, mechanical10,000,000 Operations (AC operated)
Operating frequency3000 mechanical Operations/h (AC operated) 200 Operations/h
Overvoltage categoryIII
Rated impulse withstand voltage (Uimp)8000 V AC
Shock resistance10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Drop-out voltageAC operated: 0.25 x US max - 0.6 x US min, AC operated AC operated: 0.2 x US max - 0.4 x US min, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.15 V AC x Us
Power consumption90 kW
Power consumption, pick-up, 50 Hz180 W, Pull-in power, Coil in a cold state and 1.0 x Us 210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz210 VA, Pull-in power, Coil in a cold state and 1.0 x Us 180 W, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz2.6 VA, Coil in a cold state and 1.0 x Us 2.1 W, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz2.1 W, Coil in a cold state and 1.0 x Us 2.6 VA, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max240 V
Rated control supply voltage (Us) at AC, 50 Hz - min190 V
Rated control supply voltage (Us) at AC, 60 Hz - max240 V
Rated control supply voltage (Us) at AC, 60 Hz - min190 V
Assigned motor power at 200/208 V, 60 Hz, 3-phase50 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase60 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase125 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase150 HP
Short-circuit current rating (basic rating)800 A, max. CB, SCCR (UL/CSA) 10 kA, SCCR (UL/CSA) 700 A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)350 A, max. CB, SCCR (UL/CSA) 100 kA, Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 600 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)600 A, Class J, max. Fuse, SCCR (UL/CSA) 100 kA, Fuse, SCCR (UL/CSA) 350 A, max. CB, SCCR (UL/CSA) 50 kA, CB, SCCR (UL/CSA)
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)250 A, Maximum motor rating (UL/CSA)
Mechanical & Physical
Product Length/Depth158 mm
Product Height190 mm
Product Width140 mm
Product Weight3.54 kg
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)2
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
ConnectionScrew terminals
Degree of protectionIP00
Fitted with:Suppressor circuit in actuating electronics
ProtectionFinger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)
Switching time (AC operated, make contacts, closing delay) - max60 ms
Switching time (AC operated, make contacts, opening delay) - max40 ms
Screw sizeM10, Terminal screw, Main connections M3.5, Terminal screw, Control circuit cables
Screwdriver size2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Terminal capacity (busbar)32 mm width, Main connection
Terminal capacity (copper band)Fixing with flat cable terminal or cable terminal blocks; See terminal capacity for cable terminal blocks
Terminal capacity (flexible with cable lug)50 - 185 mm²
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)1/0 - 350 MCM, Main cables 18 - 14, Control circuit cables
Terminal capacity (stranded with cable lug)50 - 185 mm²
Tightening torque1.2 Nm, Screw terminals, Control circuit cables 24 Nm, Main cable connection screw/bolt
Width across flats16 mm
Environmental & Compliance
CertificationsIEC/EN 60947-4-1 VDE 0660 UL 60947-4-1 CSA Class No.: 3211-04 CSA CSA-C22.2 No. 60947-4-1-14 UL Category Control No.: NLDX UL IEC/EN 60947 CSA File No.: 2389068 CE UL File No.: E29096
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Additional Specifications
Catalog NotesContacts according to EN 50012Also tested according to AC-3e up to 500 V.Also suitable for motors with efficiency class IE3.Conventional thermal current Ith of main contacts (1-pole, open) at 60°
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Special purpose rating of definite purpose rating280 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 1680 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 336 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 2016 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
AccessoriesFitting options auxiliary contacts: on the side: 2 x DILM1000-XHI(V)11-SI; 2 x DILM1000-XHI11-SA
ApplicationContactors for Motors
Electromagnetic compatibilityDesigned for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.

Note: Specifications are taken from the official Eaton DILM185 datasheet.

Documents & Downloads

Official technical documentation for the DILM185.

Typical Applications

Typical applications of the DILM185.

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment