Your Trusted Source for Industrial Electrical Components
Home Products Eaton Contactors DILM250/22(RA250)

DILM250/22(RA250)

Contactor

Eaton | DILM/DILH power contactors | DILM250/22(RA250)

ContactorProduct Type

Additional Technical Details

View Full Specifications
Product Weight7.065 kg
Product Length/Depth208 mm
Product Height189 mm
Product Width140 mm

Standards & Approvals

  • VDE 0660
  • UL 60947-4-1
  • IEC/EN 60947-4-1
  • UL/CSA
  • EN 45545: Fire protection on railway vehicles
  • CE marking

Typical Applications

Contactors for Motors

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

Eaton Moeller® series DILM Contactor, 380 V 400 V 132 kW, 2 N/O, 2 NC, RA 250: 110 - 250 V 40 - 60 Hz/110 - 350 V DC, AC and DC operation, Screw connection DILM250/22(RA250)

Key technical data includes Product Type: Contactor; Conventional thermal current Ith (1-pole, enclosed): 750 A; Conventional thermal current Ith (3-pole, enclosed): 300 A.

Technical Specifications

General Information
Product NameEaton Moeller® series DILM Contactor
Catalog Number208201
Model CodeDILM250/22(RA250)
EAN4015082082017
Product Length/Depth208 mm
Product Height189 mm
Product Width140 mm
Product Weight7.065 kg
CertificationsVDE 0660 UL 60947-4-1 IEC/EN 60947-4-1 UL File No.: E29096 UL Category Control No.: NLDX CSA Class No.: 3211-04 UL/CSA CSA File No. 1017510 North America (UL listed, CSA certified) EN 45545: Fire protection on railway vehicles IEC 61373: Vibration and shock, tested for category 1 class B CE marking
Catalog NotesContacts according to EN 50012Also tested according to AC-3e up to 500 V.Also suitable for motors with efficiency class IE3.EN 45545 - Fire protection on railway vehicles: Fire protection class of all plastics according to UL94: V-0 / plastic weight in total: 1.872 kgConventional thermal current Ith of main contacts (1-pole, open) at 60°
Product TypeContactor
AccessoriesFitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Electromagnetic compatibilityDesigned for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
Fitted with:Suppressor circuit in actuating electronics
Lifespan, electrical100,000 Operations (at Condensor operation)
Lifespan, mechanical10,000,000 Operations (AC operated) 10,000,000 Operations (DC operated)
Operating frequency200 Operations/h 3000 mechanical Operations/h (AC operated) 3000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance500 mΩ (Admissible transitional contact resistance - of the external control circuit device when actuating A11)
Shock resistance8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Signal level5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems
Utilization categoryAC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Voltage typeAC/DC
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid28 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid9.33 W
Rated operational current for specified heat dissipation (In)250 A
Static heat dissipation, non-current-dependent Pvs5.5 W
Electrical Characteristics
Inrush currentMax. 30 x Ie (peak)
Rated breaking capacity at 1000 V760 A
Rated breaking capacity at 220/230 V2500 A
Rated breaking capacity at 380/400 V2500 A
Rated breaking capacity at 500 V2500 A
Rated breaking capacity at 660/690 V2500 A
Rated insulation voltage (Ui)1000 V
Rated making capacity (cos phi to IEC/EN 60947)3000 A
Rated operational current (Ie)133 A at 690 V (Individual compensation, three-phase capacitors, open) 220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V430 A
Rated operational current (Ie) at AC-3, 1000 V76 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V250 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V250 A
Rated operational current (Ie) at AC-3, 440 V250 A
Rated operational current (Ie) at AC-3, 500 V250 A
Rated operational current (Ie) at AC-3, 660 V, 690 V185 A
Rated operational current (Ie) at AC-4, 1000 V76 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V200 A
Rated operational current (Ie) at AC-4, 440 V200 A
Rated operational current (Ie) at AC-4, 500 V200 A
Rated operational current (Ie) at AC-4, 660 V, 690 V150 A
Rated operational power at AC-3, 1000 V, 50 Hz108 kW
Rated operational power at AC-3, 240 V, 50 Hz85 kW
Rated operational power at AC-3, 380/400 V, 50 Hz132 kW
Rated operational power at AC-3, 415 V, 50 Hz143 kW
Rated operational power at AC-3, 440 V, 50 Hz152 kW
Rated operational power at AC-3, 500 V, 50 Hz173 kW
Rated operational power at AC-3, 690 V, 50 Hz170 kW
Rated operational power at AC-4, 1000 V, 50 Hz108 kW
Rated operational power at AC-4, 220/230 V, 50 Hz62 kW
Rated operational power at AC-4, 240 V, 50 Hz68 kW
Rated operational power at AC-4, 415 V, 50 Hz117 kW
Rated operational power at AC-4, 440 V, 50 Hz125 kW
Rated operational power at AC-4, 500 V, 50 Hz138 kW
Rated operational power at AC-4, 660/690 V, 50 Hz137 kW
Rated operational voltage (Ue) at AC - max1000 V
Safe isolation500 V AC, Between the contacts, According to EN 61140 500 V AC, Between coil and contacts, According to EN 61140
Special purpose rating of definite purpose rating1800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 250 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 300 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 2050 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Coil & Magnet System
Behavior in marginal and transitional conditionsSealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
Drop-out voltageAC operated: 0.2 x US max - 0.6 x US min, AC operated 0.2 x US max - 0.6 x US min, DC operated
Duty factor100 %
Pick-up voltage0.7 - 1.15 V AC x Us 0.7 - 1.15 V DC x Us
Power consumptionControl transformer with uk ≤ 6%
Power consumption, pick-up, 50 Hz240 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz240 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz10.5 VA, Coil in a cold state and 1.0 x Us 0 CO, Coil in a cold state and 1.0 x Us 5.5 W, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz5.5 W, Coil in a cold state and 1.0 x Us 10.5 VA, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max250 V
Rated control supply voltage (Us) at AC, 50 Hz - min110 V
Rated control supply voltage (Us) at AC, 60 Hz - max250 V
Rated control supply voltage (Us) at AC, 60 Hz - min110 V
Rated control supply voltage (Us) at DC - max250 V
Rated control supply voltage (Us) at DC - min110 V
Switching time (AC operated, make contacts, closing delay) - max100 ms
Switching time (AC operated, make contacts, opening delay) - max110 ms
Terminal Capacities
Screw sizeM3.5, Terminal screw, Control circuit cables M10, Terminal screw, Main connections
Screwdriver size2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Terminal capacity (busbar)25 mm width, Main connection
Terminal capacity (copper band)Fixing with flat cable terminal or cable terminal blocks; See terminal capacity for cable terminal blocks
Terminal capacity (flexible with cable lug)50 - 240 mm²
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)2/0 - 500 MCM, Main cables 18 - 14, Control circuit cables
Terminal capacity (stranded with cable lug)70 - 240 mm²
Tightening torque1.2 Nm, Screw terminals, Control circuit cables 24 Nm, Main cable connection screw/bolt
Width across flats16 mm
Additional Specifications
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)350 A, Maximum motor rating (UL/CSA)
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)2
Assigned motor power at 200/208 V, 60 Hz, 3-phase75 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase100 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase200 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase250 HP
Conventional thermal current Ith (1-pole, enclosed)750 A
Conventional thermal current Ith (3-pole, enclosed)300 A
Conventional thermal current Ith at 40°C (3-pole, open)430 A
Conventional thermal current Ith at 50°C (3-pole, open)380 A
Conventional thermal current Ith at 55°C (3-pole, open)365 A
Conventional thermal current Ith at 60°C (3-pole, open)350 A
Conventional thermal current Ith of main contacts (1-pole, open)875 A
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-40 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-40 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Short-circuit current rating (basic rating)700 A, max. Fuse, SCCR (UL/CSA) 600 A, max. CB, SCCR (UL/CSA) 18 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)250 A, max. CB, SCCR (UL/CSA) 18 kA, Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 700 A, Class L, max. Fuse, SCCR (UL/CSA) 700 A, Class L/450 A, Class J, max. Fuse, SCCR (UL/CSA) 18/100 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)18 kA, Fuse, SCCR (UL/CSA) 700 A, Class J, max. Fuse, SCCR (UL/CSA) 600 A, max. CB, SCCR (UL/CSA) 18 kA, CB, SCCR (UL/CSA) 700 A, Class L/450 A, Class J, max. Fuse, SCCR (UL/CSA) 18/100 kA, Fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 1000 V200 A gG/gL
Short-circuit protection rating (type 1 coordination) at 400 V400 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V400 A gG/gL
Short-circuit protection rating (type 2 coordination) at 1000 V160 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V315 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V315 A gG/gL

Note: Specifications are taken from the official Eaton DILM250/22(RA250) product data sheet.

Documents & Downloads

Official technical documentation for the DILM250/22(RA250).

Typical Applications

Typical applications of the DILM250/22(RA250).

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment