Your Trusted Source for Industrial Electrical Components
Home Products Eaton Contactors DILM40(230V50HZ,240V60HZ)

DILM40(230V50HZ,240V60HZ)

Contactor

Eaton | Contactors | DILM40(230V50HZ,240V60HZ)

ContactorProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.872 kg
Product Length/Depth132.1 mm
Product Height115 mm
Product Width55 mm

Standards & Approvals

  • CE Marked
  • IEC 60947-4-1
  • CSA Std. C22.2 No. 14-05
  • UL 508
  • EN 60947-4-1
  • CSA Certified

Typical Applications

Contactors for Motors

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series DILM contactor
Catalog Number277766
Model CodeDILM40(230V50HZ,240V60HZ)
EAN4015082777661
Product Length/Depth132.1 mm
Product Height115 mm
Product Width55 mm
Product Weight0.872 kg
CompliancesCE Marked
CertificationsIEC 60947-4-1 CSA Std. C22.2 No. 14-05 UL 508 EN 60947-4-1 CSA Certified UL Listed VDE 0660 CSA IEC/EN 60947 UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE IEC/EN 60947-4-1 UL File No.: E29096 CSA File No.: 012528 UL UL Category Control No.: NLDX CSA Class No.: 2411-03, 3211-04
Catalog NotesContacts according to EN 50012
Product TypeContactor
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical10,000,000 Operations (AC operated)
Operating frequency5000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole1.9 mΩ
Suitable forAlso motors with efficiency class IE3
TypeFull voltage non-reversing contactor
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeAC
Frame sizeFS3
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid6.6 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid2.2 W
Rated operational current for specified heat dissipation (In)40 A
Static heat dissipation, non-current-dependent Pvs4.1 W
Electrical Characteristics
Rated breaking capacity at 220/230 V400 A
Rated breaking capacity at 380/400 V400 A
Rated breaking capacity at 500 V400 A
Rated breaking capacity at 660/690 V250 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)560 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V60 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V40 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V40 A
Rated operational current (Ie) at AC-3, 440 V40 A
Rated operational current (Ie) at AC-3, 500 V40 A
Rated operational current (Ie) at AC-3, 660 V, 690 V25 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V18 A
Rated operational current (Ie) at AC-4, 440 V18 A
Rated operational current (Ie) at AC-4, 500 V18 A
Rated operational current (Ie) at AC-4, 660 V, 690 V14 A
Rated operational current (Ie) at DC-1, 110 V50 A
Rated operational current (Ie) at DC-1, 220 V45 A
Rated operational current (Ie) at DC-1, 60 V50 A
Rated operational power at AC-3, 240 V, 50 Hz13.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz18.5 kW
Rated operational power at AC-3, 415 V, 50 Hz24 kW
Rated operational power at AC-3, 440 V, 50 Hz25 kW
Rated operational power at AC-3, 500 V, 50 Hz28 kW
Rated operational power at AC-3, 690 V, 50 Hz23 kW
Rated operational power at AC-4, 220/230 V, 50 Hz5 kW
Rated operational power at AC-4, 240 V, 50 Hz5.5 kW
Rated operational power at AC-4, 415 V, 50 Hz9.5 kW
Rated operational power at AC-4, 440 V, 50 Hz10 kW
Rated operational power at AC-4, 500 V, 50 Hz11 kW
Rated operational power at AC-4, 660/690 V, 50 Hz12 kW
Rated operational voltage (Ue) at AC - max690 V
Coil & Magnet System
Arcing time10 ms
Coil voltage230-240 Vac, 50/60 Hz
Drop-out voltageAC operated: 0.6 - 0.3 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz149 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, pick-up, 60 Hz178 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Power consumption, sealing, 50 Hz16 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz 4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, sealing, 60 Hz4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 19 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Rated control supply voltage (Us) at AC, 50 Hz - max230 V
Rated control supply voltage (Us) at AC, 50 Hz - min230 V
Rated control supply voltage (Us) at AC, 60 Hz - max240 V
Rated control supply voltage (Us) at AC, 60 Hz - min240 V
Switching time (AC operated, make contacts, closing delay) - max18 ms
Switching time (AC operated, make contacts, closing delay) - min12 ms
Switching time (AC operated, make contacts, opening delay) - max13 ms
Switching time (AC operated, make contacts, opening delay) - min8 ms
Power consumption18 kW
Terminal Capacities
Screw sizeM6, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables
Screwdriver size2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)14 mm
Terminal capacity (copper band)2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cables
Terminal capacity (solid)1 x (0.75 - 16) mm², Main cables 2 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 16) mm², Main cables 1 x (0.75 - 4) mm², Control circuit cables
Terminal capacity (stranded)1 x (16 - 50) mm², Main cables 2 x (16 - 35) mm², Main cables
TerminalsSpring loaded terminals
Tightening torque1.2 Nm, Screw terminals, Control circuit cables 3.3 Nm, Screw terminals, Main cables
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 25) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.75 - 35) mm², Main cables
Terminal capacity (solid/stranded AWG)Single 14 - 1, double 14 - 2, Main cables 18 - 14, Control circuit cables
Thu Nov 05 2026
Eaton Moeller® series DILM contactor
277766
DILM40(230V50HZ,240V60HZ)
4015082777661
132.1 mm
115 mm
55 mm
0.872 kg
CE Marked
IEC 60947-4-1
Contacts according to EN 50012
Contactor
Additional Specifications
Connection to SmartWire-DTNo
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Number of polesThree-pole
Switching capacity (main contacts, general use)63 A, Maximum motor rating (UL/CSA)
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed) as main contact0
Special purpose rating of elevator control10 HP, 240 V 60 Hz 3-ph, (UL/CSA) 25 HP, 480 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 200 V 60 Hz 3-ph, (UL/CSA) 28 A, 240 V 60 Hz 3-ph, (UL/CSA) 30 HP, 600 V 60 Hz 3-ph, (UL/CSA) 32 A, 600 V 60 Hz 3-ph, (UL/CSA) 34 A, 480 V 60 Hz 3-ph, (UL/CSA) 25.3 A, 200 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of resistance air heating79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 79 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps74 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps79 A (480V 60Hz 3phase, 277V 60Hz 1phase) 79 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Conventional thermal current Ith (1-pole, enclosed)112 A
Conventional thermal current Ith (3-pole, enclosed)45 A
Conventional thermal current Ith at 55°C (3-pole, open)55 A
Conventional thermal current Ith at 60°C (3-pole, open)50 A
Conventional thermal current Ith of main contacts (1-pole, open)125 A
Assigned motor power at 115/120 V, 60 Hz, 1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase10 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase7.5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase15 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase30 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase40 HP
Short-circuit current rating (basic rating)5 kA, 250 A max. fuse, SCCR (UL/CSA) 5 kA, 250 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 150 A CLASS J max. fuse, SCCR (UL/CSA) 65 kA, 100 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 150 A CLASS J max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V125 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V80 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V50 A gG/gL
Shock resistance5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Safe isolation440 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140

Note: Specifications are taken from the official Eaton DILM40(230V50HZ,240V60HZ) product data sheet.

Documents & Downloads

Official technical documentation for the DILM40(230V50HZ,240V60HZ).

Typical Applications

Typical applications of the DILM40(230V50HZ,240V60HZ).

Motor Control
Pumps & Fans
HVAC Systems
Compressors
Conveyors
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment