Authorized Distributor
?
Contactor
| Product Weight | 0.296 kg |
| Product Length/Depth | 75 mm |
| Product Height | 68 mm |
| Product Width | 45 mm |
Motor control and switching in industrial automation and power distribution panels.
Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 4 kW, 1 N/O, 24 V DC, DC operation, Screw terminals DILM9-10(24VDC)
Key technical data includes Product Name Eaton Moeller® series DILM: contactor; Catalog Notes Contacts: according to EN 50012; Global Catalog: 276705.
| General Information | |
|---|---|
| Product Name Eaton Moeller® series DILM | contactor |
| Catalog Number | 276705 |
| EAN | 4015082767051 |
| Product Length/Depth | 75 mm |
| Product Height | 68 mm |
| Product Width | 45 mm |
| Product Weight | 0.296 kg |
| Certifications IEC/EN | 60947 CSA File No.: 012528 UL 60947-4-1 VDE 0660 CSA-C22.2 No. 60947-4-1-14 CE IEC/EN 60947-4-1 CSA Class No.: 2411-03, 3211-04 CSA UL File No.: E29096 UL Category Control No.: NLDX UL |
| Catalog Notes Contacts | according to EN 50012 |
| Global Catalog | 276705 |
| Eaton Moeller® series DILM | contactor |
| IEC/EN | 60947 |
| CSA File No. | 012528 |
| VDE | 0660 |
| CSA-C22.2 No. | 60947-4-1-14 |
| IEC/EN | 60947-4-1 |
| CSA Class No. | 2411-03, 3211-04 |
| Contacts | according to EN 50012 |
| Product Specifications | |
|---|---|
| Electrical connection type | for auxiliary- and control-current circuit Screw connection |
| Fitted with | Varistor suppressor circuit |
| Operating frequency | 9000 mechanical Operations/h (DC operated) |
| Pollution degree | 3 |
| Climatic proofing Damp heat, cyclic, | to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Connection | to SmartWire-DT Yes In conjunction with DIL-SWD SmartWire DT contactor module |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Utilization categ | ory AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
| Ambient operating temperature - max | 60 °C |
| Ambient operating temperature - | min -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - | min -25 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient storage temperature - | min -40 °C |
| Assigned | motor power at 115/120 V, 60 Hz, 1-phase 0.5 HP |
| Assigned | motor power at 200/208 V, 60 Hz, 3-phase 3 HP |
| Assigned | motor power at 230/240 V, 60 Hz, 1-phase 1.5 HP |
| Assigned | motor power at 230/240 V, 60 Hz, 3-phase 3 HP |
| Assigned | motor power at 460/480 V, 60 Hz, 3-phase 5 HP |
| Assigned | motor power at 575/600 V, 60 Hz, 3-phase 7.5 HP |
| Conventional thermal current Ith (1-pole, enclosed) | 45 A |
| Conventional thermal current Ith (3-pole, enclosed) | 18 A |
| Conventional thermal current Ith | at 55°C (3-pole, open) 21 A |
| Equipment heat dissipation, current-dependent Pvid | 0.9 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.3 W |
| Switching time (DC operated, make contacts, closing delay) - | max 31 ms |
| Switching time (DC operated, make contacts, opening delay) - | max 12 ms |
| Application Contactors | for Motors |
| Arcing time | 10 ms |
| Screwdriver size | 2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 1 |
| Number of contacts (normally closed) as main contact | 0 |
| Number of contacts (normally open contacts) | 1 |
| Number of main contacts (normally open contact) | 3 |
| Power consumption (pick-up) | at DC 4.5 W |
| Power consumption (sealing) | at DC 4.5 W |
| Rated breaking capacity at | 220/230 V 90 A |
| Rated breaking capacity at | 380/400 V 90 A |
| Rated breaking capacity at | 500 V 70 A |
| Rated breaking capacity at | 660/690 V 50 A |
| Rated control supply voltage (Us) at AC, | 50 Hz - max 0 V |
| Rated control supply voltage (Us) at AC, | 50 Hz - min 0 V |
| Rated control supply voltage (Us) at AC, | 60 Hz - max 0 V |
| Rated control supply voltage (Us) at AC, | 60 Hz - min 0 V |
| Drop-out voltage | 0.6 - 0.15 x UC, DC operated At least smoothed two-phase bridge rectifier or three-phase rectifier |
| Duty factor | 100 % |
| Emitted interference According | to EN 60947-1 |
| Interference immunity According | to EN 60947-1 |
| Lifespan, mechanical | 10,000,000 Operations (DC operated) |
| Pick-up voltage | 0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts) 0.7 - 1.3 V DC x Uc (without auxiliary contact module and at ambient air temperature + 40 °C) 0.8 - 1.1 V DC x Uc |
| Safe isolation | 400 V AC, Between coil and contacts, According to EN 61140 400 V AC, Between the contacts, According to EN 61140 |
| Screw size M3.5, Terminal | screw |
| Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA) 10 A, 600 V AC, (UL/CSA) |
| Terminal capacity (flexible | with ferrule) 1 x (0.75 - 2.5) mm² 2 x (0.75 - 2.5) mm² |
| Shock resistance | 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
| Terminal capacity (solid) | 2 x (0.75 - 2.5) mm² 1 x (0.75 - 4) mm² |
| Terminal capacity (solid/stranded AWG) Single | 18 - 10, double 18 - 14 |
| Switching capacity (main contacts, general use) | 20 A, Maximum motor rating (UL/CSA) |
| Tightening torque | 1.2 Nm, Screw terminals |
| Rated control supply voltage (Us) at DC - max | 24 V |
| Rated control supply voltage (Us) at DC - min | 24 V |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity up | to 690 V (cos phi to IEC/EN 60947) 126 A |
| Rated operational current (Ie) at AC-1, | 380 V, 400 V, 415 V 22 A |
| Rated operational current (Ie) at AC-3, | 220 V, 230 V, 240 V 9 A |
| Rated operational current (Ie) at AC-3, | 380 V, 400 V, 415 V 9 A |
| Rated operational current (Ie) at AC-3, | 440 V 9 A |
| Rated operational current (Ie) at AC-3, | 500 V 7 A |
| Rated operational current (Ie) at AC-3, | 660 V, 690 V 5 A |
| Rated operational current (Ie) at AC-4, | 220 V, 230 V, 240 V 6 A |
| Rated operational current (Ie) at AC-4, | 400 V 6 A |
| Rated operational current (Ie) at AC-4, | 440 V 6 A |
| Rated operational current (Ie) at AC-4, | 500 V 5 A |
| Rated operational current (Ie) at AC-4, | 660 V, 690 V 4.5 A |
| Rated operational current (Ie) at DC-1, | 110 V 20 A |
| Rated operational current (Ie) at DC-1, | 220 V 15 A |
| Rated operational current (Ie) at DC-1, | 60 V 20 A |
| Rated operational current | for specified heat dissipation (In) 9 A |
| Rated operational power at AC-3, | 240 V, 50 Hz 3 kW |
| Rated operational power at AC-3, | 380/400 V, 50 Hz 4 kW |
| Rated operational power at AC-3, | 415 V, 50 Hz 5.5 kW |
| Rated operational power at AC-4, | 220/230 V, 50 Hz 1.5 kW |
| Rated operational power at AC-4, | 240 V, 50 Hz 1.6 kW |
| Rated operational power at AC-4, | 380/400 V, 50 Hz 2.5 kW |
| Rated operational power at AC-4, | 415 V, 50 Hz 2.8 kW |
| Rated operational power at AC-4, | 440 V, 50 Hz 3 kW |
| Rated operational power at AC-4, | 500 V, 50 Hz 2.8 kW |
| Rated operational power at AC-4, | 660/690 V, 50 Hz 3.6 kW |
| Rated operational power (NEMA) | 3.7 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Resistance per pole | 4.6 mΩ |
| Static heat dissipation, non-current-dependent Pvs | 4.5 W |
| Stripping length (control circuit cable) | 10 mm |
| Stripping length (main cable) | 10 mm |
| Short-circuit current rating (basic rating) | 5 kA, 30 A max. fuse, SCCR (UL/CSA) 5 kA, 30 A max. CB, SCCR (UL/CSA) |
| Short-circuit current r | ating (high fault at 480 V) 100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) 65 kA, 16 A max. CB, SCCR (UL/CSA) |
| Short-circuit current r | ating (high fault at 600 V) 100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit protection rating (type | 1 coordination) at 400 V 35 A gG/gL |
| Suitable | for Also motors with efficiency class IE3 |
| Short-circuit protection rating (type | 1 coordination) at 690 V 20 A gG/gL |
| Short-circuit protection rating (type | 2 coordination) at 400 V 20 A gG/gL |
| Short-circuit protection rating (type | 2 coordination) at 690 V 16 A gG/gL |
| Special purpose rating of ballast electrical discharge lamps | 18 A (600V 60Hz 3phase, 347V 60Hz 1phase) 18 A (480V 60Hz 3phase, 277V 60Hz 1phase) |
| Special purpose rating of definite purpose rating | 9 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 54 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
| Special purpose rating of elevator control | 3 HP, 480 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA) 2 HP, 240 V 60 Hz 3-ph, (UL/CSA) 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) 5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 4.8 A, 480 V 60 Hz 3-ph, (UL/CSA) 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA) |
| Special purpose rating of refrigeration control (CSA only) | 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 10 A, FLA 600 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) |
| Special purpose rating of resistance air heating | 18 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 18 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of tungsten incandescent lamps | 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) |
| Conventional thermal current Ith | at 40°C (3-pole, open) 22 A |
| Conventional thermal current Ith | at 50°C (3-pole, open) 21 A |
| Conventional thermal current Ith | at 60°C (3-pole, open) 20 A |
| Rated operational power at AC-3, | 440 V, 50 Hz 5.5 kW |
| Rated operational power at AC-3, | 500 V, 50 Hz 4.5 kW |
| Rated operational power at AC-3, | 690 V, 50 Hz 4.5 kW |
| Actuating voltage | 24 V DC |
| Altitude Max. | 2000 m |
| Oper | ating voltage at AC, 50 Hz - min 24 V |
| Oper | ating voltage at AC, 50 Hz - max 690 V |
| Oper | ating voltage at AC, 60 Hz - min 24 V |
| Oper | ating voltage at AC, 60 Hz - max 690 V |
| Electrical connection type | for auxiliary- and control-current circuit |
| The panel builder | is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| Is the panel builder's responsibility. The specifications | for the switchgear must be observed. |
| Is the panel builder's responsibility. The specifications | for the switchgear must be observed. |
| The device | meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Meets | the product standard's requirements. |
| Meets | the product standard's requirements. |
| Meets | the product standard's requirements. |
| Meets | the product standard's requirements. |
| Meets | the product standard's requirements. |
| Does not apply, since | the entire switchgear needs to be evaluated. |
| Does not apply, since | the entire switchgear needs to be evaluated. |
| Meets | the product standard's requirements. |
| Does not apply, since | the entire switchgear needs to be evaluated. |
| Meets | the product standard's requirements. |
| Does not apply, since | the entire switchgear needs to be evaluated. |
Note: Specifications are taken from the official Eaton DILM9-10(24VDC) product data sheet.
Official technical documentation for the DILM9-10(24VDC).
Typical applications of the DILM9-10(24VDC).