4-pole contactor
| Product Weight | 0.235 kg |
| Product Length/Depth | 75 mm |
| Product Height | 68 mm |
| Product Width | 45 mm |
Contactors for 4 pole electric consumers
Eaton Moeller® series DILMP Contactor, 4 pole, AC operation, AC-1: 22 A, 230 V 50 Hz, 240 V 60 Hz, Screw terminals
Key technical data includes Catalog Notes: Contacts according to EN 50012; Product Type: 4-pole contactor; Altitude: Max. 2000 m.
| General Information | |
|---|---|
| Product Name | Eaton Moeller® series DILMP 4-pole contactor |
| Catalog Number | 276970 |
| Model Code | DILMP20(230V50HZ,240V60HZ) |
| EAN | 4015082769703 |
| Product Length/Depth | 75 mm |
| Product Height | 68 mm |
| Product Width | 45 mm |
| Product Weight | 0.235 kg |
| Certifications | UL File No.: E29096 VDE 0660 UL Category Control No.: NLDX CSA CE IEC/EN 60947 UL CSA-C22.2 No. 60947-4-1-14 UL 60947-4-1 CSA File No.: 012528 IEC/EN 60947-4-1 CSA Class No.: 2411-03, 3211-04 |
| Catalog Notes | Contacts according to EN 50012 |
| Product Type | 4-pole contactor |
| Application | Contactors for 4 pole electric consumers |
| Connection | Screw terminals |
| Degree of protection | IP20 |
| Lifespan, mechanical | 10,000,000 Operations (AC operated) 10,000,000 Operations (DC operated) |
| Operating frequency | 5000 mechanical Operations/h (DC operated) 5000 mechanical Operations/h (AC operated) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Contactors |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Residual current | 1 mA (with actuation of A1 - A2 by the electronics with "0" signal) |
| Resistance per pole | 2.5 mΩ |
| Utilization category | AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
| Voltage type | AC |
| Standards & Design Verification | |
|---|---|
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Equipment heat dissipation, current-dependent Pvid | 3 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 1 W |
| Rated operational current for specified heat dissipation (In) | 22 A |
| Static heat dissipation, non-current-dependent Pvs | 1.4 W |
| Electrical Characteristics | |
|---|---|
| Rated breaking capacity at 220/230 V | 120 A |
| Rated breaking capacity at 380/400 V | 120 A |
| Rated breaking capacity at 500 V | 100 A |
| Rated breaking capacity at 660/690 V | 70 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 144 A |
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 12 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 12 A |
| Rated operational current (Ie) at AC-3, 440 V | 12 A |
| Rated operational current (Ie) at AC-3, 500 V | 10 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 7 A |
| Rated operational current (Ie) at DC-1, 110 V | 22 A |
| Rated operational current (Ie) at DC-1, 220 V | 6 A |
| Rated operational current (Ie) at DC-1, 60 V | 22 A |
| Rated operational power at AC-1, 220/230 V, 50 Hz | 8 kW |
| Rated operational power at AC-1, 240 V, 50 Hz | 9 kW |
| Rated operational power at AC-1, 380/400 V, 50 Hz | 14 kW |
| Rated operational power at AC-1, 415 V, 50 Hz | 15 kW |
| Rated operational power at AC-1, 440 V, 50 Hz | 16 kW |
| Rated operational power at AC-1, 500 V, 50 Hz | 18 kW |
| Rated operational power at AC-1, 690 V, 50 Hz | 24 kW |
| Rated operational power at AC-3, 240 V, 50 Hz | 4 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 5.5 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 7 kW |
| Rated operational power at AC-3, 440 V, 50 Hz | 7.5 kW |
| Rated operational power at AC-3, 500 V, 50 Hz | 7 kW |
| Rated operational power at AC-3, 690 V, 50 Hz | 6.5 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Coil & Magnet System | |
|---|---|
| Drop-out voltage | AC operated: 0.6 - 0.4 x UC, AC operated |
| Duty factor | 100 % |
| Pick-up voltage | 0.8 - 1.1 V AC x Uc 0.8 - 1.1 V AC/DC x Us |
| Power consumption, pick-up, 50 Hz | 24 VA, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, pick-up, 60 Hz | 24 VA, Dual-frequency coil in a cold state and 1.0 x Us 19 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
| Power consumption, sealing, 50 Hz | 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, sealing, 60 Hz | 4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us |
| Rated control supply voltage (Us) at AC, 50 Hz - max | 230 V |
| Rated control supply voltage (Us) at AC, 50 Hz - min | 230 V |
| Rated control supply voltage (Us) at AC, 60 Hz - max | 240 V |
| Rated control supply voltage (Us) at AC, 60 Hz - min | 240 V |
| Switching time (AC operated, make contacts, closing delay) - max | 21 ms |
| Switching time (AC operated, make contacts, closing delay) - min | 15 ms |
| Switching time (AC operated, make contacts, opening delay) - max | 18 ms |
| Switching time (AC operated, make contacts, opening delay) - min | 9 ms |
| Terminal Capacities | |
|---|---|
| Screw size | M3.5, Terminal screw |
| Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver |
| Stripping length (control circuit cable) | 10 mm |
| Stripping length (main cable) | 10 mm |
| Terminal capacity (solid) | 1 x (0.75 - 4) mm² 2 x (0.75 - 2.5) mm² |
| Tightening torque | 1.2 Nm, Screw terminals |
| Terminal capacity (flexible with ferrule) | 1 x (0.75 - 1.5) mm² 2 x (0.75 - 1.5) mm² 1 x (0.75 - 2.5) mm² 2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid/stranded AWG) | 18 - 14 |
| Thu Nov 05 2026 | |
| Eaton Moeller® series DILMP 4-pole contactor | |
| 276970 | |
| DILMP20(230V50HZ,240V60HZ) | |
| 4015082769703 | |
| 75 mm | |
| 68 mm | |
| 45 mm | |
| 0.235 kg | |
| UL File No.: E29096 | |
| Contacts according to EN 50012 | |
| 4-pole contactor | |
| Max. 2000 m | |
| 60 °C | |
| 80 °C | |
| -25 °C | |
| 40 °C | |
| -25 °C | |
| -40 °C | |
| Damp heat, cyclic, to IEC 60068-2-30 | |
| 4 | |
| 0 | |
| 0 | |
| 0 | |
| 54 A | |
| 18 A | |
| 20.5 A | |
| 20 A | |
| 60 A | |
| The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | |
| Is the panel builder's responsibility. The specifications for the switchgear must be observed. | |
| Is the panel builder's responsibility. The specifications for the switchgear must be observed. | |
| The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | |
| Meets the product standard's requirements. | |
| Meets the product standard's requirements. | |
| Additional Specifications | |
|---|---|
| Connection to SmartWire-DT | No |
| Interference immunity | According to EN 60947-1 |
| Number of poles | Four-pole |
| Switching capacity (main contacts, general use) | 20 A, Maximum motor rating (UL/CSA) |
| Number of main contacts (normally open contact) | 4 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Number of contacts (normally closed) as main contact | 0 |
| Conventional thermal current Ith (1-pole, enclosed) | 54 A |
| Conventional thermal current Ith (3-pole, enclosed) | 18 A |
| Conventional thermal current Ith at 55°C (3-pole, open) | 20.5 A |
| Conventional thermal current Ith at 60°C (3-pole, open) | 20 A |
| Conventional thermal current Ith of main contacts (1-pole, open) | 60 A |
| Special purpose rating of elevator control | 5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) |
| Special purpose rating of refrigeration control (CSA only) | 60 A, LRA 480 V 60 Hz 3phase; (CSA) 10 A, FLA 600 V 60 Hz 3phase; (CSA) 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) |
| Special purpose rating of resistance air heating | 20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of tungsten incandescent lamps | 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of ballast electrical discharge lamps | 20 A (480V 60Hz 3phase, 277V 60Hz 1phase) 20 A (600V 60Hz 3phase, 347V 60Hz 1phase) |
| Short-circuit current rating (basic rating) | 5 kA, 45 A max. fuse, SCCR (UL/CSA) 5 kA, 45 A max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 480 V) | 100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 600 V) | 100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA) 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit protection rating (type 1 coordination) at 400 V | 35 A gG/gL |
| Short-circuit protection rating (type 1 coordination) at 690 V | 25 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 400 V | 20 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 690 V | 20 A gG/gL |
| Shock resistance | 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Altitude | Max. 2000 m |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Safe isolation | 400 V AC, Between coil and contacts, According to EN 61140 400 V AC, Between the contacts, According to EN 61140 |
Note: Specifications are taken from the official Eaton DILMP20(208V60HZ) product data sheet.
Official technical documentation for the DILMP20(208V60HZ).
Typical applications of the DILMP20(208V60HZ).